#HM40 Nitro-Save® Humidity Control Monitor

#1 IN CUSTOMER SATISFACTION FOR 25+ YEARS

Standard Features/Information:
  • Solid State Sensor System
  • Controls Pre-Set Relative Humidity ± 2%
  • Reduces Nitrogen Consumption up to 90% (20%RH)
    Conditions May Vary by Application
  • Sensor System Activates Solenoid as N2 Flow Required
  • Capable of Measuring and Displaying 0 - 100% RH
  • Automatic Alarm System Alerts 
    When Pre-Set Humidity Control Setting 
    not Achieved Maximum 2 Hour Cycle

Humidity Control Monitor Operating Instructions

Installation Instructions for Retro-Fit Kit

TDI's Nitro-Save Humidity Control Monitor for Desiccators

Retro-Fit Kit for Existing Desiccators - Request a Quote

The primary purpose of desiccators is to establish precise relative humidity levels to protect moisture sensitive materials in a clean environment.  

TDI has developed an economic, solid state system that accurately controls humidity and reduces nitrogen consumption.  Competitive desiccator brands offer expensive moisture control systems that are dependent on electro mechanical switches to control moisture flow.  These systems are subject to maintenance with repair/replacement in the long run with compromised reliability.  Ironically, most desiccators in service have no RH% moisture control and often consume excess nitrogen to compensate.

The #HM40 Nitro-Save® Humidity Control Monitor accuracy is  ± 2۬% RH at 20-80% RH and ± 5% at less than 20% RH.  

The Nitro-Save® includes a solenoid control valve and internal sensor system to regulate the nitrogen flow in response to the high humidity set point.  Whenever the humidity rises 2% above the set point the control valve will turn on.  Once the humidity decreases 2% below the set point, the control valve will turn off.  Each time the control valve turns on, the monitor will begin a 2 hour timer.  If at the end of 2 hours the humidity has not reached 2% below the set point, the High Humidity Alarm will sound.  Under normal operating conditions the alarm at the end of the 2 hour cycle will indicate a problem such as a lack of nitrogen flowrate or the cabinet door remained open.

The High Humidity Set Point has already been programmed to 20% RH, which represents general electronics requirements.  The RH % settings can be increased for less critical humidity control or decreased for more critical humidity control.

The Nitro-Save® Humidity Control Monitor significantly reduces the nitrogen required to maintain pre-set humidity (RH%) in TDI's Desiccator Cabinets up to 90%+ reduction in nitrogen consumption in 
many applications. (See Graph)

Conditions May Vary by Application

Accuracy = ±2%RH 20-80%RH / ±5% <20%RH

TDI Independent Test Results
To maintain low moisture conditions in TDI Desiccator Cabinets, a constant dry nitrogen gas supply is required, connected to the nitrogen flowmeter on the desiccator cabinet.  The flowmeter regulates the nitrogen gas flow (cu/ft/hr) to the plenum chamber of the desiccator cabinet with the nitrogen gas distributed uniformly through the perforated inside wall of the plenum chamber into each compartment.

TDI Desiccator Ultra Nitro-Flow System

All TDI Acrylic Desiccators are constructed with Ultra Nitro-Flow compartment flow-throughs, which achieve a single pressure and atmosphere condition throughout the desiccator.  This unique design allows maximum gas flow in both the vertical and horizontal directions and reduces higher moisture humidity conditions between compartments.

This flow design allows for a single automatic bleeder valve per multiple compartment cabinet and eliminates the need for expensive outlet valves for each compartment, required in typical competitor cabinets.  The bleeder valve is located in the bottom of the lowest compartment and serves as an efficient outlet drain for the heavier high moisture atmosphere within the cabinet.  This design also allows for a single #HM40 Nitro-Save® Humidity Control Monitor sensor system for multiple compartment desiccators.

Nitrogen Gas Distribution Diagram

TDI Desiccators - Ultra Nitro-Flow System

The Ultra Nitro-Flow System offers a highly efficient/economical design to provide rapid recovery to pre-set RH% levels when doors are opened in normal usage functions.

In cases where the Nitro-Save is running when the doors are opened, a positive pressure of Nitrogen flow extends throughout the cabinet plenum wall to all compartments and exits through the open compartment.  This precludes any higher humidity room air back fill into the cabinet.

The desiccator cabinet and room atmospheric pressures are similar when the Nitro-Save has achieved pre-set RH% settings and is in the off position.  When the doors are opened, air movement between the compartment and the room is slight during the brief timeframe of exposure with minimal RH% level increase in the desiccator.

Cleanrooms generally operate in a 45/55% RH range and this would represent the highest increase condition possible inside an open cabinet compartment.

Desiccator Care & Use  |  Acrylic Material Datasheet  |  Static Dissipative Acrylic Datasheet  |  Reduce Nitrogen Consumption

Phone: (520) 799-8000 | Email: sales@tdiinternational.com  © Copyright 2000-2012 TDI International, Inc.

TDI Home  |  Catalog  |  Newsletter  |  Terms  |  Privacy Policy |  Contact Us  |  Conversion Charts  |  Site Map

TDI International - Desiccators, Tweezers & Handtools for Cleanrooms, Labs, Electronics Assembly
Products Catalog Newsletter About Us Contact Us Site Map

TDI Home

HANDTOOLS:
 Cutters
 Cutter & Plier Kits
 Diamond Scribes
 Micro Mini Tools
 Micro Shears
 Mirrors
 Pin Vises
 Pliers
 Scalpels
 Scissors
 Screwdrivers
 Spatulas & Probes
 Tweezers
 Tweezer Kits
 Vacuum Pick Up
 
EQUIPMENT:
 Chairs
 Desiccators
 Dispensers
 Gloveboxes
 Nitrogen Generators
 Nitro-Save®
 Workstations