TDI NITRO-GENŽ Nitrogen Generator - Depressurizing the System | |
![]() | WARNING! - You must wear eye and hearing protection during the depressurizing process to avoid possible injury. |
| Follow
these steps before performing system maintenance.
1. Wear eye and hearing personal protection equipment. 2. Close the main shutoff (compressed air inlet) valve. 3. Turn the inlet control valve to the on position. 4. Turn the start-up purge control valve to the start-up purge position. 5. Be sure the inlet pressure gauge reads zero. 6. Turn the inlet control valve to the off position. 7. Turn the start-up purge control valve to the normal operation position. | |