TDI NITRO-GENŽ Nitrogen
Generator - Maintenance |
|
 |
WARNING! - Only
trained maintenance technicians who are familiar with high-pressure
air systems and who have read the user guide should perform
maintenance on the NITRO-GENŽ. |
|
|
 |
The NITRO-GENŽ remains
pressurized after shutdown. Before performing maintenance,
filter changes or opening piping, you must depressurize the
system. Depressurizing the system prevents the uncontrolled
escape of high-pressure gas and possible injury. |
|
|
Important Maintenance Notes:
- To ensure peak performance from your
NITRO-GENŽ, you must also maintain all related equipment -
such as the air compressor and air dryer - according to the
manufacturer's recommendations.
- You may need to shorten the filter
replacement interval due to excessive runtime, poor air quality, or
other conditions.
|
|
Preventative
Maintenance Schedule |
| Action |
Frequency
(at 8hrs. Daily Runtime) |
| Daily |
Weekly |
Monthly |
Quarterly |
Annually |
Bi-Annually |
| Check for
Air / Nitrogen Leaks |
X |
|
|
|
|
|
| Check that
Filter Drains Work |
X |
|
|
|
|
|
| Record
Pressure / Purity |
|
X |
|
|
|
|
| Calibrate
Oxygen Analyzer** |
|
|
X |
|
|
|
| Clean
Filter Bowls |
|
|
|
X |
|
|
| Check
Pressure Safety Valve(s) |
|
|
|
X |
|
|
| Check
Manual Valves |
|
|
|
X |
|
|
| Change
Carbon Filter Element |
|
|
|
|
X |
|
| Replace
Oxygen Sensor |
|
|
|
|
|
X |
| Change
Coalescing Element |
|
|
|
|
|
X |
|
|
| **One month is the
longest possible interval between analyzer calibrations. It is
recommended that you calibrate more frequently and even daily, if possible. |
|
Phone: (520) 799-8000 | Email: sales@tdiinternational.com ©
Copyright 2000-2012 TDI International, Inc.
TDI Home |
Catalog |
Newsletter |
Terms |
Privacy Policy |
Contact Us |
Conversion Charts |
Site Map |