Hygrometer Indicates cabinet humidity level.  Not required when 
#HM40 Humidity Control Monitor
is utilized.

TDI #5506 HYGROMETER INSTRUCTIONS

  1. LCD Digital thermometer display in °C or °F and hygrometer in %RH.

  2. Indoor temperature and indoor relative humidity measurement display simultaneously.

  3. Measuring range:

    • Temperature: 0°C to 50°C (32°F to 122°F)

    • Humidity: 25%RH to 95%RH

  4. Memory Functions - automatically records maximum and minimum readings of temperature and humidity.

  5. Resolution:

    • Resolution of temperature: 1°C (1°F)

    • Resolution of humidity: 1%RH

  6. Accuracy of temperature measurement

    • +/-1°C (+/-2°F): 0°C to 40°C (32°F to 104°F)

    • +/-2°c (+/-4°F): Below 0°C (32°F) or over 40°C (104°F)

  7. Accuracy of humidity measurement

    • +/-5%RH: 40%RH to 80%RH between 15°C and 48°C (59°F to 104°F)

    • +/-7%RH: Below 40%RH or over 80%RH between 15°C and 40°C (59°F to 104°F)

  8. Relative humidity measurement is temperature-compensated.

  9. Battery life:  more than one year.  Remove red tabs from battery compartment prior to use.

MEMORY FUNCTION

Hygrometer Meter Function - Reset:

Press the Min button once, the LCD will display "MIN" in the bottom right corner, and display the minimum relative humidity in memory.  Press the Memory Reset button and the minimum relative humidity reading in memory will reset to the current humidity reading.  Press the Min button again to erase the "MIN" display and bring you back to the mode of displaying actual relative humidity.

Press the Max button once, the LCD will display "MAX" on the bottom middle part of the LCD and display the maximum relative humidity in memory.  Press the Memory Reset button and the maximum relative humidity reading in memory will reset to the current humidity reading.  Press the Max button again to erase the "MAX" display and bring you back to the mode of displaying the actual relative humidity.