HM40 NITRO-SAVE® HUMIDITY CONTROL MONITOR

"The Technical Source!"

STANDARD FEATURES:
  • Preset Relative Humidity (± 2% RH)
  • Up to 75% Reduction in Nitrogen Consumption
  • Retro-Fit Kits Available for Existing Cabinets

Electrical: 120V AC/DC Power Supply UL Approved
                 (Most Foreign Plugs Available)

Finally an economical, reliable sensor instrument to pre-set RH and significantly reduce N2 consumption. 

The Nitro-Save® Humidity Control Monitor significantly reduces the nitrogen required to maintain pre-set humidity (RH) in desiccator cabinets.  The Nitro-Save® includes a solenoid control valve and internal sensor system to regulate the nitrogen flow in response to the high humidity set point.

TDI Nitro-Save Humidity Control Monitor
The #HM40 Nitro-Save® Humidity Control Monitor accuracy is  ± 2۬% at 20-80% RH and ± 5% at less than 20% RH.  The Nitro-Save® is capable of measuring and displaying humidities in the range: 0-100% RH.

Whenever the humidity rises 2% above the set point the control valve will turn on.  Once the humidity decreases 2% below the set point, the control valve will turn off.  Each time the control valve turns on, the monitor will begin a 2 hour timer.  If at the end of 2 hours the humidity has not reached 2% below the set point, the High Humidity Alarm will sound.  Under normal operating conditions the alarm at the end of the 2 hour cycle will indicate a problem such as a lack of nitrogen flowrate or the cabinet door remained open.

The High Humidity Set Point has already been programmed to 20% RH, which represents general electronics requirements.  The RH % settings can be increased for less critical humidity control or decreased for more critical humidity control.

Nitro-Save on 2 Door Desiccator

Nitro-Save® in Acrylic Cabinet Pocket

All TDI Desiccator Cabinets are constructed with our Ultra Nitro-Flow® compartment flow thrus which achieve a single pressure throughout the cabinet.

This unique system also allows for a single #HM40 Nitro-Save® Humidity Control Monitor sensor system for multiple compartment cabinets.

The Nitro-Save® Humidity Control Monitor significantly reduces the nitrogen required to maintain pre-set humidity (RH%) in TDI's Desiccator Cabinets with up to 75% reduction in nitrogen consumption.

Humidity Control Monitor Operating Instructions

Retro-Fit Kit Installation

Request a Quote for a TDI Desiccator Storage Cabinet

(Hygrometer is not required when #HM40 humidity control monitor is utilized)

Disk Drive Assembly | Electronics / Medical Device Assembly | Life Sciences / Pharmaceutical / Biotech

Laboratories  |  Universities / Research & Development  |  Forensics / Crime Labs

Assembly  |  Cleanrooms  |  Ergonomics  |  ESD Safe  |  Class 0 CDM Compliant Tweezers

Ph:(520) 799-8000 | Fax: (520) 799-8002 | Email: sales@tdiinternational.com  © Copyright 2000-2009 TDI International, Inc.

TDI Home  |  About Us  |  Request a Catalog  |  Hot Deals!  |  Site Map  |  Privacy Policy